Title |
Experiments & numerical analysis of charge accumulation and flat band voltage shifts in irradiated MIS capacitor |
Keywords |
MIS Capacitor ; Radiation ; continuity Eguations |
Abstract |
To investigate the mechanism generated by irradiation in the insulator layer irradiated MIS (Metal - Insulator - Semiconductor) device, the various types of MIS capacitors depending on insulator thickness, insulator types and implanted impurities are fabricated on the P-type wafer. MIS capacitors exposed by 1Mrad Co^{60} .gamma.-ray are measured for flat band voltage and charge density shifts pre- and post-irradiation. The measuring results of post-irradiation show the flat band voltage shifting toward negative direction and charge density increasing regardless of parameters. This results have a good agreement with calculated data by computer simulation. Si_{3}N_{4} layers have a good radiation-hardness than SiO_{2} layers compared to the results of post-irradiation. Also, radiation-induced negative trap is discovered in the implanted insulator layer. Using numerical analysis, four continuty equations (conduction-band electrons continuity equation, valence-band holes continuity equation, trapped electrons continuity equation, trapped holes continuity equation) are solved and charge distributions according to the distance and Si-Insulator interface states are investigated. |