Title |
Wireless Parallel Operation of High Voltage DC Pourer Supply using Steady-state Estimation |
Keywords |
Parallel operation ; wireless ; droop ; steady state estimation ; DC power supply |
Abstract |
This paper presents an improved droop method which minimizes the voltage droop of a parallel-connected power supply Conventionally, the droop method has been used to achieve a simple structure and no-interconnections among power sources. However, it has a trade-off between output voltage regulation and load sharing accuracy In this paper, the droop is minimized with a current and droop gain control using steady-stage estimation. The proposed method can achieve both good voltage regulation and good load sharing. A design example of two 10㎸, 100㎃ parallel modules is made and tested to verify the proposed current-sharing method. |