Abstract |
Piezoelectric properties of PMN-PZT ceramics with CeO_2 impurity were investigated. Mechanical quality factor, Q_m of 1792, 1285 and the electromechanical coupling coefficient, k_p of 0.52, 0.54 were obtained from the specimen with 0.25 and 0.5 mole % CeO_2 respectively. Curie temperature was decreased with the addition of CeO_2 while the electric coercive field was proportional to the amount of impurity. Based on the system ceramics with 0.5 mole % cerium oxide, a Rosen type piezoelectric transformer was fabricated and tested. Voltage step-up ratios of 230 and 13 were obtained from the transformer at no load and 100 kΩ resistance, respectively. Experimental results showed a potential of the transformer for the practical use coupled with the expected strength increase by the grain size refinement. |