Title |
A Study on the Technology Measuring Partial Discharge for Long Term Aging Experiments of Insulation Materials |
Authors |
선종호(Seon, Jong-Ho) ; 김광화(Kim, Gwang-Hwa) ; 박정후(Park, Jeong-Hu) ; 조정수(Jo, Jeong-Su) |
Keywords |
Partial discharge ; φ-q-n ; VXI system ; Digital measurment ; Aging ; Ensulation |
Abstract |
This paper described the measurement technology to analyze the partial discharge characteristics for long term aging of insulations. This system was consisted of high voltage generation and measurement part, PD detection part, digital conversion and signal processing part. We used the VXI system for digital conversion and signal processing part. In the digital conversion part, we studied the error of partial discharge magnitude and memory capacity for reading digital signal with the sampling rate. In the signal processing part, we showed the program algorithm to count pulses and read peak values of partial discharge. The allowable minimum sampling rate of digizer was decided to 250kS/s through analyzing test. We confirmed that this system was very useful in the study of φ-q-n characteristics of long term PD experiments with specimens being consisted of internal void defects and CIGRE II electrodes. |