Title |
A Study of Electromagnetic Interference in Power Line Communication |
Authors |
이진택(Lee Jin-Taek) ; 천동완(Chun Dong-Wan) ; 박영진(Park Young-Jin) ; 이원태(Lee Won-Tae) ; 신철재(Shin Chul-Chai) |
Keywords |
PLC (Power-Line Communication) ; Conductive Noise ; DMT ; Emissive E-Field |
Abstract |
In this paper, we studied the emissive electric field due to the communication signal and the noise in medium voltage power-line. There are many types of conductive noise in power-line channel, which gives rise to radiation. And if the DMT carrier signal was excited, the current by this term was added to the current by noise and, generate radiation. We calculated input impedance by means of signal input network model of medium voltage power-line channel for calculating these currents. We calculated currents by input impedance and, calculated the emissive electric field by this calculated currents. From the measurement results, we knew that the measured results are very similar to the calculated results and if the input signal power level was higher than -40 dBm, the emissive electric field exceeds FCC radiation limit level 69.5 dBμV/m. |