Title |
A Study on the Improvement of the JADE Algorithm |
Authors |
윤형로(Yoon H.R.) ; 이진술(Lee J.S.) ; 전대근(Jeon D.K.) ; 이경중(Lee K.J.) |
Abstract |
In this paper, we proposed an IJADE(Improved joint approximate diagonalisation of eigenmatrices) which use high order statistics instead of second order statistics for data whitening. For simulation, we artificially construct signals mixed with two ECG signals, 60Hz power line interference and 16Hz sine signal and then put them into a JADE and an IJADE. To evaluate the performance of separated ECG signal in each algorithm, we have adopted indices such as kurtosis, standard deviation ratio, correlation coefficient and euclidean distance. As a results, IJ ADE showed theimproved performances as kurtosis of 2 %, standard deviation ratio of 0.2194, and Euclidean distance of 0.07 except correlation coefficient showing similar value. In conclusion, the proposed IJADE showed a good performance in separating ECG and a possibilities in applying to the various biological signal. |