• 대한전기학회
Mobile QR Code QR CODE : The Transactions of the Korean Institute of Electrical Engineers
  • COPE
  • kcse
  • 한국과학기술단체총연합회
  • 한국학술지인용색인
  • Scopus
  • crossref
  • orcid
Title A Study on the Pattern Recognition of EMG Signals for Head Motion Recognition
Authors 이태우 ; 전창익 ; 이영석 ; 유세근 ; 김성환
Page pp.103-110
ISSN 1975-8359
Keywords electromyography(EMG) ; pattern recognition ; mIAR
Abstract This paper proposes a new method on the EMG AR(autoregressive) modeling in pattern recognition for various head motions. The proper electrode placement in applying AR or cepstral coefficients for EMG signature discrimination is investigated. EMG signals are measured for different 10 motions with two electrode arrangements simultaneously. Electrode pairs are located separately on dominant muscles(S-type arrangement), because the bandwidth of signals obtained from S-type placement is wider than that from C-type(closely in the region between muscles). From the result of EMG pattern recognition test, the proposed mIAR(modified integrated mean autoregressive model) technique improves the recognitions rate around 17-21% compared with other the AR and cepstral methods.