Title |
A Study on the Cost and Efficacy Improvement of AC PDP |
Authors |
신중홍(Shin, Joong-Hong) ; 이돈규(Lee, Don-Kyu) ; 윤초롬(Yoon, Cho-Rom) ; 허정은(Heo, Jeong-Eun) ; 박정후(Park, Chung-Hoo) |
Keywords |
PDP ; MgO ; Metal Electrode ; High Efficacy |
Abstract |
In order to improve cost and efficacy of AC PDP with metal discharge electrodes, a new II-type metal electrodes are suggested. The suggested asymmetrical II-type metal electrode is improved in the luminance, power and efficacy than the conventional metal electrode by 7.5%, 6%, and 14%, respectively. The efficacy of the suggested asymmetrical II-type metal electrode is almost the same with the conventional ITO electrode. Moreover, the address time of the II-type metal electrode is shorter than the conventional ITO electrode. |