Title |
Characteristics Analysis According to Switching of Switched Reluctance Generator |
Authors |
오재석(Oh, Jae-Seok) ; 오주환(Oh, Ju-Hwan) ; 권병일(Kwon, Byung-Il) |
Keywords |
SRG ; turn-on ; turn-off voltage ; exciting voltage ; generation |
Abstract |
A switched reluctance generator(SRG) has simple magnetic structure, and needs simple power electronic driving circuit. But, a SRG are no windings or permanent magnets on the rotor, and there are concentrated windings placed around each salient pole on the stator. Because of the characteristics of time-sharing excitation, the control of SRG is very flexible. And there are several parameters for controlling SRG, such as switch turn-on angle, switch turn-off angle, and exciting voltage and controlling mode, all these will affect the generation greatly. A SRG has positive torque at increasing inductance region and negative torque at decreasing inductance region. In this paper, we studied characteristics about the switch turn-on and off angles according to switch method for constant output voltage of the fixed speed SRG. It is the acoustic noise and torque ripple characteristics. Characteristics for a switch angle and method are presented by experiment using a 50W SRG with 12/8 poles. |