| Title | 
	Electrical Insulation Characteristics according to Environmental Degradation of a Connector for Carbon Fiber Screened Cable  | 
					
	| DOI | 
	https://doi.org/10.5370/KIEE.2019.68.9.1163 | 
					
	| Keywords | 
	 Carbon fiber; Screened cable; Environmental degradation; Electrical insulatio | 
					
	| Abstract | 
	Carbon fiber, because of difficulty in maintaining its shape, is required extra care in connections, and its problem is that fiber can easily break due to the binding post-tensioning force. So, a new type of screened cable connector which can reduce carbon fiber's breaking or cutting and also minimize contact resistance in connections needs to be developed. In this paper, a conductive spring-applied, gland-type cable connector was designed and manufactured, and its applicability was reviewed through measurement of contact resistance of the connector.  |