• 대한전기학회
Mobile QR Code QR CODE : The Transactions of the Korean Institute of Electrical Engineers
  • COPE
  • kcse
  • 한국과학기술단체총연합회
  • 한국학술지인용색인
  • Scopus
  • crossref
  • orcid
Title Analysis of Common-mode Voltage and Shaft Voltage of IPMSM Accoring to Inverter Parameters
Authors 이열경(Yeol-Kyeong Lee) ; 임준혁(Jun-Hyuk Im) ; 허진(Jin Hur)
DOI https://doi.org/10.5370/KIEE.2022.71.1.071
Page pp.71-78
ISSN 1975-8359
Keywords Bearing current; Bearing fault; Shaft voltage; Permanent magnet synchronous motor
Abstract Cmmon-mode voltage (CMV) occurs in the pulse width modulated (PWM) method inverter of fast switching. The CMV induces shaft voltage and bearing current because of electrical interaction with the parasitic capacitance of the motor. CMV and shaft voltage are considered major causes of bearing fault. Motor fault poses a risk of accidents. Therefore, analysis of the CMV and shaft voltage of the motor is required. This paper analyzes the effect of parameter changes in inverter on CMV and shaft voltage. The parameters include DC link voltage, switching frequency, and carrier wave phase shift. An Equivalent simulation model is constructed through MATLAB/SIMULINK. The parasitic capacitance of the motor is obtained according to its structure. Comparative analysis of CMV, shaft voltage is carried out through simulation. Changes in motor output due to carrier wave phase shift are included. Finally, validation through experiments is included.