Title |
A Study on Slip Selection in the Equivalent Circuit Test Method of 750W Three-Phase Induction Motor |
Authors |
박용준(Yong-Joon Park) ; 허진(Jin Hur) |
DOI |
https://doi.org/10.5370/KIEE.2022.71.6.856 |
Keywords |
Dynamometer method; Equivalent circuit method; Reliability; Slip selection; Three-phase Induction motor |
Abstract |
Manufacturers are using the equivalent circuit test method that can be used as a method to calculate the characteristics of the 750W three-phase motor without a motor-specific tester called the dynamometer. By selecting the slip within the limited range of the calculated output that varies depending on the slip, the test result by improved equivalent circuit method can be obtained close to the result measured by the dynamometer. And by analyzing the reproducibility of these test results and the error with the dynamometer method, and confirming their validity, it is intended to be used as a standard for the slip selection method. |