• 대한전기학회
Mobile QR Code QR CODE : The Transactions of the Korean Institute of Electrical Engineers
  • COPE
  • kcse
  • 한국과학기술단체총연합회
  • 한국학술지인용색인
  • Scopus
  • crossref
  • orcid

References

1 
M. Akbar, M. Ahmad, may 1999, Failure study of metal-oxide surge arresters, Electr. Power Syst, Vol. 50, No. 2, pp. 79-82DOI
2 
S. A. Naveed, M. Venu Gopala Rao, J. Amaranath, S. Kamakshaiah, B. P. Singh, 2005, The features of high voltage motor interruption by vacuum circuit breaker with different cable lengths, in CEIDP ’05. 2005 Annual Report Conference on Electrical Insulation and Dielectric Phenomena, 2005., Nashville, TN, USA, pp. 705-708DOI
3 
E. P. Dick, B. K. Gupta, P. Pillai, A. Narang, T. S. Lauber, D. K. Sharma, Dec. 1988, Prestriking voltages associated with motor breaker closing, IEEE Trans. Energy Convers, Vol. 3, No. 4, pp. 855-863DOI
4 
V. Jayasree, B. Nanda, D. B. P. Singh, 2012, Transient over Voltage Due to Switching Operation of Industrial Motor by Vacuum Circuit Breaker and Suppression of Surges, Vol. 3, No. 9Google Search
5 
KINS, 2015, Automatically shut down the reactor due to the shutdown of the reactor coolant pump ‘B’ due to damage to the surge protector of the Kori No. 4 Unit, the results of the rating assessment Resolution agenda 2015-4Google Search
6 
KINS, 2015, Automatically shut down the reactor due to the shutdown of the reactor coolant pump ‘B’ due to damage to the surge protector of the Kori No. 4 Unit, the results of the rating assessment Resolution agenda 2015-4Google Search
7 
KINS, 2019, The results of the rating evaluation of Stop No.1 reactor coolant pump and automatic shutdown of the reactor due to damage to the surge protector of Wolseong No. 3 reactor, Resolution agenda, 2019-2Google Search
8 
OHIO BRASS, 2019, Surge Arresters, Catalog 702, pp. 17Google Search
9 
C. Heinrich, V. Hinrichsen, Jan 2001, Diagnostics and monitoring of metal-oxide surge arresters in high-voltage networks- comparison of existing and newly developed procedures, IEEE Trans. Power Deliv., Vol. 16, No. 1, pp. 138-143DOI
10 
J. Lundquist, L. Stenstrom, A. Schei, B. Hansen, Oct 1990, New method for measurement of the resistive leakage currents of metal-oxide surge arresters in service, IEEE Trans. Power Deliv., Vol. 5, No. 4, pp. 1811-1822DOI
11 
G. R. S. Lira, E. G. Costa, Apr 2013, MOSA Monitoring Technique Based on Analysis of Total Leakage Current, IEEE Trans. Power Deliv., Vol. 28, No. 2, pp. 1057-1062DOI
12 
G. R. S. Lira, E. G. Costa, T. V. Ferreira, Mar 2014, Metal-oxide surge arrester monitoring and diagnosis by self-organizing maps, Electr. Power Syst. Res., Vol. 108, pp. 315-321DOI
13 
V. Hinrichsen, 1999, Online monitoring of high-voltage metal- oxide surge arresters by wireless passive surface acoustic wave (SAW) temperature sensors, in 11th International Symposium on High-Voltage Engineering (ISH 99), London, UK, Vol. 1999DOI
14 
IEEE C62.21 Surge Voltge Protective Equipment.pdfGoogle Search
15 
OHIO BRASS, 2019, IEEE Guide for the Application of Surge Voltage Pro- tective Equipment on AC Rotating Machinery 1000 Volts and Greater, IEEEDOI
16 
International Electrotechnical Commission, 2009, International Elec- trotechnical Commission, and Technical Committee 86, Fibre optic interconnecting devices and passive components- basic test and measurement procedures. Part 3-3, Part 3-3,. Geneva: International Electrotechnical CommissionGoogle Search
17 
P. Pinceti, M. Giannettoni, Apr 1999, A simplified model for zinc oxide surge arresters, IEEE Trans. Power Deliv., Vol. 14, No. 2, pp. 393-398DOI
18 
S. Dau, Sep. 2012, Modelling of metal oxide surge arresters as elements of overvoltage protection systems, International Conference on Lightning Protection (ICLP), Vienna, Austria, pp. 1-5DOI
19 
B. Badrzadeh, oct. 2012, Transient recovery voltages caused by capacitor switching in wind power plants, in 2012 IEEE Industry Applications Society Annual Meeting, Las Vegas, NV, USA, pp. 1-8DOI
20 
B. Kondala Rao, Gopal Gajjar, 2006, Development and application of vacuum circuit breaker model in electro- magnetic transient simulation, in 2006 IEEE Power India ConferenceDOI
21 
M. T. Glinkowski, M. R. Gutierrez, D. Braun, Jan 1997, Voltage escalation and reignition behavior of vacuum generator circuit breakers during load shedding, IEEE Trans. Power Deliv., Vol. 12, No. 1, pp. 219-226DOI
22 
A. Borghetti, F. Napolitano, C. A. Nucci, M. Paolone, M. Sultan, N. Tripaldi, Transient Recovery Voltages in Vacuum Circuit Breakers Generated by the Interruption of Inrush Currents of Large Motors, p. 8.Google Search
23 
J. Helmer, M. Lindmayer, 1996, Mathematical modeling of the high frequency behavior of vacuum interrupters and comparison with measured transients in power systems, in Proceedings of 17th International Symposium on Dis- charges and Electrical Insulation in Vacuum Berkeley CA USA, Vol. 1, pp. 323-331DOI
24 
V. Jayasree, B. Nanda, D. B. P. Singh, 2012, Transient over Voltage Due to Switching Operation of Industrial Motor by Vacuum Circuit Breaker and Suppression of Surges, Vol. 3, No. 9, pp. 4Google Search