• 대한전기학회
Mobile QR Code QR CODE : The Transactions of the Korean Institute of Electrical Engineers
  • COPE
  • kcse
  • 한국과학기술단체총연합회
  • 한국학술지인용색인
  • Scopus
  • crossref
  • orcid

References

1 
R. Morin, R. Bartnikas, and P. Menard, “A Three-Phase Multi-Stress Accelerated Electrical Aging Test Facility for Stator Bars,” IEEE Transactions on Electrical Conversion, vol. 15, no. 2, pp. 149-156, 2000.DOI
2 
H. D. Kim, and T. S. Kong, “Assessment of Insulation Deterioration in Stator Windings of High Voltage Motor,” The Transactions of The Korean Institute of Electrical Engineers, vol. 61, no. 5, pp. 711-716, May 2012.DOI
3 
H. D. Kim, and T. S. Kong, “Characteristics of Insulation Diagnosis and Failure in 6.6kV Motor Stator Windings,” Journal of The Korean Institute of Electrical and Electronic Material Engineers, vol. 25, no. 4, pp. 309-314, 2012.DOI
4 
J. H. Dymond, Nick Stranges, Karim Younsi, and J. E. Hayward, “Stator Winding Failures : Contamination, Surface Discharge, Tracking,” IEEE Transactions on Industry Applications, vol. 38, no. 2, pp. 577-583, March/April 2002.DOI
5 
H. Kim et al., “Experience With Stator Insulation Testing and Turn/Phase Insulation Failures in the Power Generation Industry,” IEEE Transactions on Industry Applications, vol. 54, no. 3, pp. 2225-2236, May-June 2018.DOI
6 
A. Litinsky et al., “Aging of Corona Protection Material on Rotating Machine,” IEEE Electrical Insulation Conference, pp. 356-359, 2017.DOI
7 
Lingyan Lin al., “Development and Discharge Characteristics of Surface Tracking on the Interface Between the PD Suppression Coatings Outside of Stator Winding Slots,” IEEE Transactions on Dielectrics and Electrical Insulation, vol. 30, no. 1, pp. 421-428, 2023.DOI
8 
H. Yoshida, and K. Umemoto, “Insulation Diagnosis for Rotating Machine Insulation,” IEEE Transactions on Electrical Insulation, vol. EI-21, no. 6, pp. 1021-1025, 1986.DOI
9 
H. D. Kim, Y. J. Lee, and Y. H. Ju, “Characteristics of Insulation Aging in Large Generator Stator Windings,” The Transactions of The Korean Institute of Electrical Engineers, vol. 58, no. 7, pp. 1375-1379, 2009.URL
10 
J. Y. Koo, J. H. Kwak, and H. D. Kim, “Analysis of the Trend of Insulation Aging in Stator Winding of Off-Line and On-Line Steam Turbine Generator,” The Transactions of The Korean Institute of Electrical Engineers, vol. 73, no. 3, pp. 625-630, 2024.URL
11 
H. D. Kim, “Analysis of Insulation Condition in High Voltage Motor Stator Windings following Cleaning and Insulation Reinforcement,” The Journal of the Korean Institute of Electrical and Electronic Material Engineers, vol. 25, no. 6, pp. 474-480, 2012.DOI
12 
H. Zhu, C. Morton, and S. Cherukupalli, “Quality Evaluation of Stator Coils and Bars under Thermal Cycling Stress,” Conference Record of the 2006 IEEE International Symposium on Electrical Insulation, pp. 384-387, 2006.DOI
13 
J. Y. Koo, J. H. Kwak, and H. D. Kim, “Analysis of Transition Cause of Partial Discharge Patterns in High Voltage Motor Stator Windings,” The Transactions of The Korean Institute of Electrical Engineers, vol. 73, no. 8, pp. 1456-1460, 2024.URL
14 
H. D. Kim, “Characteristics of Insulation Diagnosis and Failure in Gas Turbine Generator Stator Windings,” Journal of Electrical Engineering & Technology, vol. 9, no. 1, pp. 280-285, 2014.URL
15 
Y. Luo, Z. Li, and H. Wang, “A Review of Online Partial Discharge Measurement of Large Generators,” Energies, vol. 10, 1694, pp. 1-32, 2017.DOI