• 대한전기학회
Mobile QR Code QR CODE : The Transactions of the Korean Institute of Electrical Engineers
  • COPE
  • kcse
  • 한국과학기술단체총연합회
  • 한국학술지인용색인
  • Scopus
  • crossref
  • orcid

References

1 
J. M. Park, S. H. Kim, K. H. Jeong, Y. J. Kim, "Offshore MTDC Transmission Expansion for Renewable Energy Scale-up in Korean Power System: DC Highway," Journal of Electrical Engineering & Technology, vol. 18, pp. 2483-2493, 2023. DOI
2 
A. R. Lee, G. H. Ryu, J. Y. Park, Y. G. Kim, C. J. Moon, "Tracking Trends for Offshore Wind Energy Industries and Infrastructures in the South Korea: Focused on the Jeonnam Shinan 8.2GW and Ulsan 6GW Offshore Wind Farm Projects," Renewable Energy – Recent Advances, IntechOpen, 2023. DOI
3 
S. Choi, H. Lee, J. Kim, K. Son, "An Economic Impact Analysis of Transmission and Substation Network Investments for Accelerating Renewable Energy Expansion in South Korea: Modeling and Policy Perspectives," Land, vol. 15, no. 1, pp. 107, 2026. DOI
4 
IEC, "High-Voltage Switchgear and Controlgear – Part 306: Guide to IEC 62271-100, IEC 62271-1 and Other IEC Standards Related to Alternating Current Circuit-Breakers," IEC/TR 62271-306:2012+A1:2018, International Electrotechnical Commission, Geneva, Switzerland, 2018. Google Search
5 
IEC, "High-Voltage Switchgear and Controlgear – Part 1: Common Specifications for Alternating Current Switchgear and Controlgear," IEC 62271-1:2017, International Electrotechnical Commission, Geneva, Switzerland, 2017. Google Search
6 
IEC, "Guidance Concerning the Permissible Temperature Rise for Parts of Electrical Equipment, in Particular for Terminals," IEC/TR 60943:1998+AMD1:2008, International Electrotechnical Commission, Geneva, Switzerland, 2009. Google Search
7 
M. Stosur, P. Dawidowski, M. Szewczyk, P. Balcerek, "Thermal Behaviour Analyses of Gas-Insulated Switchgear Compartment Using Thermal Network Method," IET Generation, Transmission & Distribution, vol. 10, no. 12, pp. 2833-2841, 2016. DOI
8 
ISO-NE (ISO New England), "Operating Procedure No. 19 – Transmission Operations (OP-19)," Technical Report, ISO New England Inc., Holyoke, MA, USA Google Search
9 
ISO-NE (ISO New England), "Planning Procedure No. 7 – Procedures for Determining and Implementing Transmission Facility Ratings in New England (PP-7)," Technical Report, ISO New England Inc., Holyoke, MA, USA Google Search
10 
IEEE, "IEEE Standard for Ratings and Requirements for AC High-Voltage Circuit Breakers with Rated Maximum Voltage Above 1000 V," IEEE C37.04-2018, Institute of Electrical and Electronics Engineers, New York, USA, 2018. Google Search
11 
ENTSO-E, "Operation Handbook – Policy 5: Emergency Operations, RG CE OH," European Network of Transmission System Operators for Electricity, Brussels, Belgium, 2015. Google Search
12 
T. Kobayashi, H. Chida, H. Kajino, N. Kato, "Overview of JEC-2390 Standard (General Requirements for High-voltage Switchgear and Controlgear)," IEEJ Transactions on Power and Energy, vol. 134, no. 10, pp. 843-848, 2014. DOI
13 
American Transmission Company (ATC), "Substation Equipment Ampacity Ratings, Criteria Document No. CR-0063," Technical Report, American Transmission Company LLC, Waukesha, WI, USA Google Search
14 
National Grid Electricity Transmission plc, "Circuit-Breakers Technical Specification, TS 3.02.01, Issue 1," National Grid Electricity Transmission plc, London, UK, 2014. Google Search
15 
IEC, "High-Voltage Switchgear and Controlgear – Part 100: Alternating-Current Circuit-Breakers," IEC 62271-100:2021, International Electrotechnical Commission, Geneva, Switzerland, 2021. DOI